Load Cell Configuration
Stable Weight Detection
Set STABLE DELTA WEIGHT = 2.0g and STABLE DELTA TIME = 10 (1s) to filter noise. For 1g steps, use MANUAL RESOLUTION with value 1.0
Maximum Responsiveness
Set FILTER LEVEL = 0 and DENOISE FILTER = Disabled for fastest readings.
Test & Calibration
Live Measurements
| Measurement |
Value |
Unit |
| Net Weight | - | [g] |
| Gross Weight | - | [g] |
| Tare Weight | - | [g] |
| ADC Filtered | - | |
| Pieces Count | - | |
Status Register
Calibration Procedure
1. Configure reference weight in Config page
2. Empty scale, click TARE ACQUISITION
3. Place reference weight, wait for stability
4. Click ACCEPT REFERENCE WEIGHT
Test Printer
Quick Test
Send a simple test label to verify printer connectivity.
Custom ZPL
Paste your own ZPL code and send it to the printer.
ZPL Examples
Simple Text:
^XA^FO50,50^ADN,36,20^FDHello World^FS^XZ
Barcode:
^XA^FO50,50^BY2^BCN,100,Y,N,N^FD123456789^FS^XZ
QR Code:
^XA^FO50,50^BQN,2,5^FDQA,https://example.com^FS^XZ